SolarQuadrant
TR EN
Join the pilot

Solar PV monitoring and alerts

See every kilowatt-hour your plant is losing.

SolarQuadrant brings data from inverters of different brands into one dashboard and tells you when production drops or a device goes silent. It shows which string is at fault, how much energy it has cost and when the panels need cleaning.

In pilot Built together with pilot plants.

Why

Production losses are usually silent.

01

A separate portal for every brand

Different inverter brands mean separate accounts, screens and units. Seeing the whole plant at a glance is hard.

02

Losses are noticed late

An inverter or a string can underperform for weeks. The gap only shows up when the month's production falls short.

03

Where, and how much?

An alert says "something is wrong" but not which string, or how many kWh it has cost. Soiling and faults get mixed up.

Features

Everything you want to see in a plant, in one dashboard.

Even with a single plant you get string-level faults, performance ratio, energy loss, soiling and a maintenance log.

Strings and MPPT

Find faults at string level

Strings with the same tilt and azimuth are compared with each other; a string falling behind its group raises an alert. Weather events such as clouds are filtered out, and nothing is evaluated at night. A separate warning fires when MPPT voltage drops below expected.

Inv 1
Inv 2
Inv 3

Multi-brand

All your inverters in one dashboard

Connect your brand accounts; every inverter's power, energy and status code on one screen, in the same units. Each plant's last data time is always visible.

Manufacturer cloud APIOn-site gatewayManually added device

Expected power and PR

Performance ratio without sensors

Irradiance and temperature from a weather service are combined with your panels' tilt and azimuth; expected power and daily PR are calculated per inverter and per plant.

Energy loss

See what a fault costs, in kWh

Every open fault and anomaly alert accumulates an estimate of the energy not produced. When the alert closes, the total stays on record and in reports.

0kWh

Example: a string fault lasting three days

Soiling and maintenance

Know when to clean the panels

The PR trend over the last 14 days is tracked; cleaning is recommended when the drop exceeds 5%. Cleaning and maintenance records are taken into account.

Cleaning recommended

Reports

Daily, monthly and yearly reports

Production per inverter, equivalent hours, availability, year-over-year comparison, energy loss per alert and carbon savings. Download as PDF or Excel; daily summaries, weekly and monthly reports are sent automatically.

Notifications

The news comes to you

Email, mobile notification and Telegram message within 10 minutes of the alert condition reaching the data. Acknowledge, close and review alert history.

EmailMobile pushTelegram

Alerts

Seven alert rules, one goal: catch losses early.

Every alert says what happened and where. When the condition clears, the alert closes itself; its history stays on record.

  1. 01

    Data gap

    No data from the plant for 60 minutes.

  2. 02

    Inverter fault

    An inverter enters a fault state, with the manufacturer's status code.

  3. 03

    Zero production in daylight

    An inverter is not producing while the sun is up.

  4. 04

    Low production

    An inverter's daily specific yield (kWh/kWp) is more than 15% below the median of the inverters in the same plant. The threshold is adjustable per plant.

  5. 05

    String anomaly

    A string falls more than 30% behind its group of the same tilt and azimuth, for two consecutive readings.

  6. 06

    MPPT voltage

    A warning when measured voltage is below 85% of expected; an MPPT offline alarm below 30 V.

  7. 07

    Gateway offline

    The on-site gateway stays silent for 7 minutes.

A sample day

07:12NormalPlant started producing
11:48WarningInverter 2, MPPT 1: voltage below expected
13:05AlarmInverter 3, string 2: production below expected
13:41NormalInverter 2, MPPT 1: voltage back to normal

Sample data. Times are shown in the plant's local time.

How it works

Start monitoring in three steps.

1

Connect

Enter the API credentials of your inverter brand's cloud account; your plant and inverters come in. No site visit, about 15 minutes.

2

Describe

Enter panel count, panel power (Wp), tilt and azimuth for your strings. All strings of an inverter can be set in one go.

3

Monitor and act

When an alert comes in, see where it is and how much it has cost. Log the maintenance, share the report.

On-site gateway

No cloud connection? We read the inverter on site.

If your inverter has no cloud account, or you want more frequent data, a gateway installed on site reads the inverter directly over RS485 using Modbus RTU. That data flows into the same dashboard and the same alerts as cloud API data.

  • A plant can have more than one gateway.
  • Each gateway is identified by its own key; data from unknown devices is rejected.
  • Firmware and settings are updated remotely; if an update fails, the gateway keeps running the previous version.
  • Last seen time, hardware and firmware versions are shown in the dashboard.

Our criteria

Not promises. Criteria.

Four of the first release's acceptance criteria, being verified with pilot plants.

0min

Time to add a plant connected through a cloud API

0min

Maximum time from the alert condition reaching the data to the notification

0%

Maximum deviation of daily, monthly and yearly production from the manufacturer's portal

0min

Time without data before a plant raises a "no data" alert

Who it's for

See your plant with your own eyes.

Plant owners

Commercial and industrial solar

Rooftop and ground-mounted plants of industrial, commercial and agricultural irrigation sites. Even with a single plant, every analysis works for you.

  • Inverters of different brands in one dashboard
  • String-level faults and energy loss
  • Soiling tracking and cleaning recommendations
  • Regular reports by email and Telegram

With your team

Share access, keep control

The account owner adds plants, invites users and changes alert settings. Viewers can only see and receive alerts.

  • Owner and viewer roles
  • Each customer account's data is kept separate
  • Your API credentials are stored encrypted
  • English and Turkish interface

FAQ

Frequently asked questions

What is SolarQuadrant?

SolarQuadrant is a multi-brand monitoring and alerting platform for solar PV plants. It brings data from inverters of different brands into one dashboard and notifies you when production drops or a device goes silent. It offers string-level fault detection, performance ratio (PR), energy loss estimates, soiling tracking, a maintenance log and regular reports.

Which inverter brands does it support?

Data comes from inverter manufacturers' cloud APIs and from an on-site gateway. The first supported brands are being chosen together with pilot plants; the first candidate is Sungrow (iSolarCloud). The gateway first reads Sungrow inverters over Modbus RTU. Tell us which brand your plant uses; we prioritise by pilot plants.

Do I need an irradiance sensor?

No. Expected power and PR are calculated from weather-service irradiance and temperature, using your panels' tilt and azimuth. In addition, inverters in the same plant and strings facing the same direction are compared with each other, which needs no sensor either.

How long does setup take? Is a site visit needed?

A plant connected through a cloud API is added in about 15 minutes by entering the API credentials; no site visit is needed. Plants without a cloud connection get an on-site gateway.

Which alerts are there, and how am I notified?

Data gap, inverter fault, zero production in daylight, low production compared with sibling inverters, string anomaly, MPPT voltage and gateway offline. You are notified by email, mobile notification and Telegram within 10 minutes of the alert condition reaching the data.

How do you estimate soiling?

We look at the PR trend over the last 14 days. A drop of more than 5% shows "cleaning recommended", more than 2% shows "watching". The last cleaning date is taken into account; with less than 7 days of PR data, no estimate is made.

Is my data safe?

Each customer account is kept separate; one account's data is never visible to another, which is verified by automated tests. Your inverter API credentials and Telegram token are encrypted in the database with AES-256-GCM and never appear in logs.

Does it do SCADA or power plant control (PPC)?

No. The first release is a monitoring, analysis and alerting platform; it has no active or reactive power control.

When can I use it, and what does it cost?

SolarQuadrant is being built with pilot plants. To join the pilot program and discuss pricing, write to info@solarquadrant.com.

Pilot program

Be among the first to monitor your plant with us.

We are working with pilot plants. Tell us your inverter brand, installed capacity and plant location, and we will get back to you.